Case Studies: Pennsylvania

Route 66 Bridge Deck, Pennsylvania, USA – 30 Years and Counting

The recent refurbishment of a Route 66 bridge deck south of Kittanning, PA, provided a unique opportunity to assess the performance of galvanized rebar after more than 30 years of service. The bridge was built in 1973 using galvanized rebar in the deck. The bridge deck remains in excellent condition but the Pennsylvania DOT wanted to replace the post and beam medial barrier with a more secure concrete Jersey barrier. This required removing the entire middle section of the deck and exposing the galvanized rebar for inspection. Test found the chloride content in the concrete surrounding the rebar to be 5 lbs/yd 3, far exceeding the chloride threshold for corrosion of black rebar.

Inspection of the rebar showed that coating was in excellent condition with coating thicknesses still exceeding ASTM A767 specification for new galvanized rebar. Also noted during concrete removal was the tenacious bond of the galvanized rear to the surrounding concrete, thereby confirming the excellent bond strength obtained from galvanized coatings. No refurbishment of the concrete deck was required; the original rebar remained in place when the Jersey barrier was poured.

Athens Bridge, Pennsylvania

The Pennsylvania DOT has specified galvanized reinforcement for decades. One such bridge, the Athens Bridge, was built in 1973 and is an eleven-span, four-lane, divided bridge that uses only hot-dip galvanized reinforcing bars. The Athens bridge deck was inspected eight years after installation to ensure that hot-dip galvanizing was protecting the bridge from corrosion. Concrete cores were drilled and an analysis of chloride contamination and coating thickness was conducted. The chloride levels found in the cores exhibited concentrations between 1.8 to 7.9 lbs/yd3 of concrete, where the high end of these concentrations is well above the threshold for active corrosion to occur on bare steel. Despite these extremely corrosive conditions, the coating thickness measurements indicated galvanized coatings in excess of 15 mils (approximately three times the coating thickness required on newly-galvanized rebar according to ASTM A 767). In all instances, the galvanized rebar showed no signs of corrosion.

The Athens Bridge was later inspected in 1991 and 2001, and the analysis generated similar results. No sign of active corrosion on the galvanized reinforcement was found and coating thickness measurements reported were in excess of ten mils. These current coating thicknesses indicate an estimated 40-plus years of
additional maintenance-free corrosion protection.

  View Bridge Inspection Summary  

Germantown Avenue Bridge over Wissahickon Creek 

Details


Year Galvanized

2003

Sectors

Bridge & Highway
Duplex Systems

Environment

Suburban

Location

Philadelphia, PA United States

Reasons for Galvanizing

Corrosion Performance